Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1025-04838
Parcel: 110110460

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1025-04838
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2025 Residential Building - Standard APPROVED
10/31/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/03/2025 Addressing Validation REQUIRES RESUBMIT Please include the full property address on all pages of the site plan and resubmit after all other reviews are complete.
10/31/2025 Residential Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-1025-04838
2634 N AVENIDA CAROLINA – R-1
Demo existing carport and storage room and building new storage & carport (1st Review)

TRANSMITTAL DATE: October 31, 2025

COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Provide fully dimensioned building elevations so that perimeter yard setback requirements can be determined.

2. Provide a setback dimension from the proposed structure to the north property line. The minimum setback to interior property lines are the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Per UDC Article 6.4.5.B.2 setbacks for carport type structures are measured from the post supporting the structure as long as the overhang is not more than 2’-0”. As it appears that the structure will have a roof overhang exceeding 4’ show the allowed 2’-0” overhang line on the plot plan and provide a setback dimension. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. For a carport type structure this measurement is from design grade to the bottom of the roof joists. If the distance from the allowed 2’ overhang to the north property line is less than 6’ a Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

3. The 8’ dimension shown from what appears to be the face of curb to the west property line is not correct. Per paving plan I-678, sheet 1, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-678, the distance should be 9’.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
10/03/2025 PDSD Application Completeness Express REVIEW COMPLETED