Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1025-04832
Parcel: 122153310

Address:
3222 E SENECA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1025-04832
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2025 Residential Building - Standard APPROVED Note: Approval is for porch only.
10/31/2025 Residential Zoning APPROVED
10/31/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/07/2025 Site Engineering - Standard REQUIRES RESUBMIT Permit: TC-RES-1025-04832
Location: 3222 E SENECA ST
Review Date: 10/7/2025
Site Engineering Comments:
1. This site resides with the City of Tucson Christmas wash floodplain.
2. Due to the Floodplain status and development requirements, it will be required that this permit be submitted as two separate building permits – One permit for the porch and one permit for the sheds.
3. Each of the residential permit will require their own separate floodplain use (FPU) permit which can be submitted for within the sub-records of the parent permits through TDC online.
4. Moving forward, permit TC-RES-1025-04832 can be reviewed in regard to the scope of the porch construction, and the new residential permit must cover the storage sheds.
5. For the FPU permit for the porch, please submit a cost estimate form that will break down the total cost into separate lines, separating labor, materials/equipment, and warranties/fees associated with the project. Ensure to have company/contractor letterhead on the document for proper documentation. This cost estimate will be used for substantial improvement calculations.
6. For the FPU permit for the sheds, Flood venting will be required according to Tucson Code PART II Chapter 26, Section 26-11.2.(8). For resubmission of the building permit for the sheds and submission for the flood plain use permit, have the flood vents delineated on the construction plans along with a detail showing the dimensions of the vents
7. A minimum of two openings will be required for each shed. The vents will have a total net area of not less than one square inch for every square foot of enclosed area. Openings may be equipped with screens, louvers, valves, or other coverings or devices if they permit the automatic entry and exit of floodwater.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
10/03/2025 PDSD Application Completeness Express REVIEW COMPLETED