Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-06336
Parcel: 125070910

Address:
2527 E 5TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL POOL v.1

Permit Number - TC-RES-1024-06336
Review Name: RESIDENTIAL POOL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/18/2024 Historic NOT REQUIRED The project location is outside the local HPZ. No historic review required.
Contact Michael.Taku@tucsonaz.gov
11/18/2024 Site Engineering NOT REQUIRED
11/27/2024 Site Zoning NOT REQUIRED
11/27/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/05/2024 Residential Building REQUIRES RESUBMIT PROJECT: NEW POOL
ACTIVITY NO. TC-RES-1024-06336
ADDRESS/PARCEL: 2527 E 5TH ST/125-07-0910


The scope of this plan review covers architectural, plumbing, mechanical, energy conservation, and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.


COMMENTS:

1. Concrete is misspelled on the plan set on the dimensions on the east side of the property.
2. Please indicate all gates and their corresponding swings on the plan set, this includes ones going to the front yard.
3. Please show the overhead electric line running from pole in the alley to the house.
4. Please indicate the distance from the overhead electric line to the swimming pool.
5. Please indicate what is being demolished in the backyard for the proposed swimming pool – there are existing walls in the backyard that must be addressed.
6. Please indicate where the new walls are being placed on the plan set and which are existing and which are new.
7. The pool must be a minimum 5’ from the garage for foundation surcharge, please move the pool 1’ to the east.
8. Please show on the Pool Engineering Details which rebar schedule is being used to account for the foundation surcharge on the pool from the existing garage. Special Engineering may be necessary from AMTEC.

Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set.

Resubmittals will not be accepted without the revision letter.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov
11/01/2024 PDSD Application Completeness Express REVIEW COMPLETED