Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.3
Permit Number - TC-RES-1024-06325
Review Name: RESIDENTIAL SIMPLE REVIEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/07/2024 | PDSD Application Completeness Express | REQUIRES RESUBMIT | Missing comment response letter. Please resubmit your plans and a detailed Comment Response Letter. This letter should notate any changes applied, per the reviewer's previous comments: 1. Aerial views of the property show the overhead service conductors passing over the roof of the porch structure. The overhead service conductor over the structure requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. Show the mast height required to achieve the necessary clearance. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For any questions contact: building_official@tucsonaz.gov |