Permit Number: TC-RES-1024-06251
Parcel: 134233950

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-1024-06251
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/27/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/06/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1024-06251 (517 S GRINNELL AV TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC).
1. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability for 115 MPH, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems
2. Provide complete roof framing information for determining load carrying capacity for the roof structure. Show all load bearing locations. Demonstrate the ability for supporting the existing and additional dead load, or provide an engineer’s calculation, design, and seal for verifying the truss load carrying capacity. R324.4 Equipment shall be positively attached to the roof structure with a minimum of one connection per 10 sf of equipment (minimum of two connections per piece of equipment). Point loads exceeding 45 lbs shall require a structural load analysis by licensed Arizona engineer.
3. Add missing engineering stamps to the structural parts of the plans.
Building_official@tucsonaz.gov
11/27/2024 Site Engineering REQUIRES RESUBMIT TC-RES-1024-06251
517 S GRINNELL AV

Site engineering comments are as follows:
1. This project is within a regulated floodplain, Alamo Wash, and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home

NOTE: A cost estimate of materials and labor from your contractor in the form of a pdf attachment will be required to complete the FUP application. Please have separate lines for cost of materials, and cost of labor. Thank you.
Ryan Insalaco
ryan.insalaco@tucsonaz.gov
10/29/2024 PDSD Application Completeness Express REVIEW COMPLETED