Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-06213
Parcel: 133291180

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1024-06213
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/05/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-1024-06213
8501 E APPOMATTOX ST. – R-1
Detached Shed (2nd Review)

TRANSMITTAL DATE: February 5, 2025

Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9.

1. This comment was not addressed. No setback waiver for the north perimeter yard was provided. There should be a waiver from the property owners at 8500 & 8510 E. Shiloh St. for the reduced north perimeter yard setback. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As height dimensions from design grade were not provided. Zoning has added 6” to the dimensions provided on sheet A3.0, 10’8” + 6” = 11’-2” x .6667 = 7.45’ or 7’-6” required perimeter yard setback to the north property line. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). At a minimum a neighbors setback waiver is required, UDC Article 6.6.2.D To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

2. Zoning acknowledges that the shed was relocated closer to the east property line an that a neighbors setback waiver was provided.

3. Clarify why there are two (2) sheet T1.0 provided in the plan set.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
01/08/2025 PDSD Application Completeness Express REVIEW COMPLETED