Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-06194
Parcel: 11106375A

Address:
3227 E GLENN ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-1024-06194
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/25/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1024-06194 (3227 E GLENN ST TUCSON, AZ 85716)

2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC)

1. The 1/2” black iron pipe going from the main line to the AC, is undersized for the given length (32’) and appliance demand (100,000btuh). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe). See notes on the plan.
2. The 1/2” black iron pipe going from the main line to the stove, is undersized for the given length (28’) and appliance demand (100,000btuh). See notes on the plan.
10/25/2024 PDSD Application Completeness Express REVIEW COMPLETED