Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL POOL v.2
Permit Number - TC-RES-1024-06168
Review Name: RESIDENTIAL POOL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2024 | Site Engineering | NOT REQUIRED | |||
| 11/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/28/2024 | Residential Building | REQUIRES RESUBMIT | PROJECT: POOL RENOVATION ACTIVITY NO. TC-RES-1024-06168 ADDRESS/PARCEL: 2844 E 1st St/ 125-02-0410 The scope of this plan review covers architectural, plumbing, mechanical, energy conservation, and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. COMMENTS: 1. Please indicate on your construction drawing the original shape of the existing pool and spa. 2. Please include a sheet showing exactly what the structural changes to the pool are, i.e., where it has been made smaller, how the stairs have changed. 3. Based on aerial photos – this pool currently has a diving board, which indicates a depth of greater than 8’. Please show all means of egress from the pool. 4. Please show the existing automatic pool cover being used as a barrier and show what changes are being made to the existing one to ensure that it continues to uphold ASTM standards. 5. Include a separate revised plot plan showing the dimensions of the redesigned pool in relation to all structures on site, including but not limited to the house, walls, and any gates. 6. Provide an engineering letter as well as engineering details to support the structural changes being made to the existing swimming pool. 7. The swimming pool is being shown as being built in 1975, a dust control permit is necessary be necessary. 8. The swimming pool is being shown as being built in 1975, we will also need a NESHAP permit through Pima County unless the applicant can prove that there is no asbestos present in the existing pool – both in the shotcrete and the original plaster. Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set. Resubmittals will not be accepted without the revision letter. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov |
||
| 10/25/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |