Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-06168
Parcel: 125020410

Address:
2844 E 1ST ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL POOL v.2

Permit Number - TC-RES-1024-06168
Review Name: RESIDENTIAL POOL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/13/2024 Site Engineering NOT REQUIRED
11/13/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/28/2024 Residential Building REQUIRES RESUBMIT PROJECT: POOL RENOVATION
ACTIVITY NO. TC-RES-1024-06168
ADDRESS/PARCEL: 2844 E 1st St/ 125-02-0410

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation, and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

COMMENTS:
1. Please indicate on your construction drawing the original shape of the existing pool and spa.
2. Please include a sheet showing exactly what the structural changes to the pool are, i.e., where it has been made smaller, how the stairs have changed.
3. Based on aerial photos – this pool currently has a diving board, which indicates a depth of greater than 8’. Please show all means of egress from the pool.
4. Please show the existing automatic pool cover being used as a barrier and show what changes are being made to the existing one to ensure that it continues to uphold ASTM standards.
5. Include a separate revised plot plan showing the dimensions of the redesigned pool in relation to all structures on site, including but not limited to the house, walls, and any gates.
6. Provide an engineering letter as well as engineering details to support the structural changes being made to the existing swimming pool.
7. The swimming pool is being shown as being built in 1975, a dust control permit is necessary be necessary.
8. The swimming pool is being shown as being built in 1975, we will also need a NESHAP permit through Pima County unless the applicant can prove that there is no asbestos present in the existing pool – both in the shotcrete and the original plaster.


Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set.

Resubmittals will not be accepted without the revision letter.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov
10/25/2024 PDSD Application Completeness Express REVIEW COMPLETED