Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-06151
Parcel: 140060020

Review Status: In Review

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1024-06151
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2024 Site Engineering NOT REQUIRED
10/25/2024 Site Landscape NOT REQUIRED
N/A Bldg Permits - Post Review PENDING ASSIGNMENT
N/A Site Zoning PENDING ASSIGNMENT
10/31/2024 Residential Building REQUIRES RESUBMIT TC-RES-1024-06151
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Note the 2018 IRC reference on the plans.

Provide a response letter on separate file with the updated construction plan set.


SITE PLAN:

1. The metal roof structure may not extend to a point closer than 2 feet from the adjoining (neighboring) property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within the fire spread separation space along the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2) between the support posts of the structure.

SECTIONS - DETAILS:

1. Provide an engineer’s calculation, design and seal for the site fence exceeding 7’ in height above grade, R301.1.3. The engineer’s performance design will account for wind loads required by Table R301.2(1) Climatic and Geographic Design Criteria. Or reduce the fence height no greater than 7 feet above grade.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
10/23/2024 PDSD Application Completeness REVIEW COMPLETED