Permit Number: TC-RES-1024-06100
Parcel: 126151410

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW REVISION v.2

Permit Number - TC-RES-1024-06100
Review Name: RESIDENTIAL SIMPLE REVIEW REVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1024-06100 (4481 E LA JOLLA CI TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received.

1.Modifications and additions to the gas line require that the existing system be enlarged to meet the total demand based on the new length and load, G2412.3, G2412.4. The addition of the 2nd furnace requires that the main line from the meter to the first junction point be upsized per Table G2413.4(1) (Metallic Pipe) For questions: Building_Official@tucsonaz.gov
10/31/2024 PDSD Application Completeness Express REVIEW COMPLETED