Permit Number: TC-RES-1024-06093
Parcel: 116184160

Address:
901 W ESTRADA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1024-06093
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2024 Site Engineering NOT REQUIRED
11/21/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-1024-06093 (901 W ESTRADA ST TUCSON, AZ 85745)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

Energy Review:
1. Tucson is in climate zone 2B. The simplified prescribed energy values for ceiling R=38, N1102.1. Show a means of achieving the prescriptive value at each assembly on the plans. >>> Ceiling insulation provided is less than the prescribed R value.
2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing (closed cell spray or rigid board tight to the roof sheathing), R806.5. This condensation control provision is necessary for code compliance and may be a single layer of air-impermeable insulation or layered with batt insulation for achieving the total required roof R-value.

Plumbing Review:
3. Show cleanouts as required by P3005.2.1.
4. Show two-way cleanout only in the locations specified in P3005.2.3.

Electrical Review:
5. Provide GFCI protection for all 15 and 20 amp receptacles in the laundry area, E3902.9.
6. Hallways of 10’ or more in length require a receptacle, E3901.10. Provide a minimum of one receptacle in the hallway between the master bedroom and the study.
7. Conductors on circuit 9/11 are undersized. OCPD(Breaker) for copper conductor may not exceed 20A for #12 AWG conductors as required by IRC E3705.5.3, NEC 240.4(D)(small conductors). Provide minimum #10AWG CU conductors for this circuit.
8. Show Arc-Fault Protection of all interior 15A & 20A circuits serving outlet locations (except garage, exterior and bathroom outlets) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
11/21/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Ramiro Olivarez
Planner, Zoning Review Section

PROJECT: TC-RES-1024-06093
901 W ESTRADA ST TUCSON, AZ 85745 – R-2 Zone
Additions (1st Review)

TRANSMITTAL DATE: 11/21/2024

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. Comment: Remove the aerial overlay from the site plan.
2. Comment: Dimension the property including the northeast curved radius. Lot 18 dimensions can be found at: https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=11085.
3. Comment: Draw, label, and dimension the centerline of Melwood Av. (17’) to the face of curb and the face of curb (8’) to the property line. The paving plan can be found on sheet 3 of Plan # I-602: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-602.
4. Comment: Dimension the Alley (16’).
5. Comment: On the elevations dimension the height of the wall from design grade (the ground) to the top of the wall.
6. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards.


If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov
10/21/2024 PDSD Application Completeness Express REVIEW COMPLETED