Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-06078
Parcel: 11003102D

Review Status: In Review

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1024-06078
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2024 Fire New Construction NOT REQUIRED
10/23/2024 Site Landscape NOT REQUIRED
N/A Bldg Permits - Post Review PENDING ASSIGNMENT
N/A Site Engineering PENDING ASSIGNMENT
N/A Site Zoning PENDING ASSIGNMENT
10/30/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-1024-06078 (4111 E FORT LOWELL RD TUCSON, AZ 85712)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

Electrical Review:
1. Show locations of each smoke alarm, R314. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity.
2. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. Show the circuits that each new outlet is connected to.
3. Designate the circuit number (that correlates to the panel schedule) at the location of each receptacle, switch, or utilization equipment, E3404.12.
4. Show a minimum of one 20 AMP branch circuit in the laundry area; this circuit may not serve other locations, E3703.3 and 3901.8.
5. Provide mini-split circuiting information and manufacturer’s specification sheets.

Plumbing Review:
6. Show the sewer line connection from the washer to the main sewer line.
7. Notate and specify all piping materials for the sewer lines, P3002.1.
8. Notate and specify all piping materials and sizes for the hot/cold water lines, P2903.1

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
10/18/2024 PDSD Application Completeness REVIEW COMPLETED