Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1024-06057
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/17/2024 | PDSD Application Completeness Express | REQUIRES RESUBMIT | Unable to process. Your submittal is incomplete. Please resubmit your plans and include the following: 1. Provide/update HVAC demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. 2. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J. 3. Modifications and additions to the gas line may require that the existing system be enlarged to meet the total demand based on the new length and load, or a new dedicated line may be required for the additional HVAC loads, G2412.3, G2412.4. A gas piping template is required for this permit submittal. Gas piping template: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/gas_piping_template.pdf 4. Last, you must remove, shade screen, the fence demo and reinstallations of of your site plan. This work must be permitted separately. For questions: building_official@tucsonaz.gov |