10/23/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/23/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1024-05897 (342 N COUNTRY CLUB RD TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. Provide a complete gas piping template showing the connection and length from the meter to the attached pool heater, G2401.1, R301.1: Include pipe size, type (Black Iron, Poly) and length. Provide appliance demands, G2413.4.1. 2. Provide total demand from all appliances, G2413.2. 3. Pool heaters generally have a demand of approximately 400,000 BTUs. This would require a 1” pipe connection from the meter to the heater, Table G2413.4(1) (Metallic Pipe). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
10/22/2024 | PDSD Application Completeness | REVIEW COMPLETED |