Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1024-05717
Parcel: 134081550

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1024-05717
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2024 PDSD Application Completeness Express REQUIRES RESUBMIT Unable to process. For a new gas line addition, modification to the gas line or increase in gas demand, you will need to provide a complete gas pipe plan for sizing compliance verification. G2412.3, G2412.4

1. Modification to the gas line system and meter, require the submission of a gas pipeline template, G2401.1, R301.1: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_template_1.pdf

See also: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf

2. Provide a complete gas piping template showing the connection from the meter to all gas appliances, include all future connections/demand to the new gas line. Include pipe size, type and length. Provide appliance demands. G2413.4.1

3. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe).

Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.

Step-by-step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

For questions: Building_official@tucsonaz.gov