Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1023-09184
Parcel: 130056900

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1023-09184
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/01/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
11/01/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1023-09184 (2660 S COUNTRY CLUB RD TUCSON, AZ 85713)

1. Note and specify all piping materials and sizes, P2609, G2413.1.
2. Provide the length from the meter to the farthest appliance. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.
11/01/2023 PDSD Application Completeness REVIEW COMPLETED