Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-1023-09163
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/01/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1023-09163 (8760 E BEARS PATH RD TUCSON, AZ 85749) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Electrical Review: 1. Show the OCPD/breaker, inside the generator, sized according to the specifications, E3705. 2. Provide conductors sized according to E3704.1. See Table 3705.1 for conductor ampacity ratings. 3. Provide electrical load calculations for the backup load panel, to show generator backup is sufficient, according to E3704.2. 4. Show conductor type and size for all lines, N1-2, E1-2, T1-2. Show all conduit sizes and types, Table E3907.8 and 2017 NEC chapter 9. Also show the control conductors from the generator to the ATS. Plumbing/Gas Review: 5. Note and specify all piping materials and sizes, P2609. Show the max gas demand on the plans. 6. Show connection lengths from gas meter to the generator. G2401.1, , G2413.1, R301.1: See https://www.tucsonaz.gov/files/pdsd/permits/GAS_HANDOUT_2018_IRC_2019.2.4.pdf https://www.tucsonaz.gov/files/pdsd/permits/Gas_Piping_Template.pdf https://www.tucsonaz.gov/files/pdsd/permits/Sample_Gas_Template_0.pdf 7. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 10/31/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |