Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1023-09100
Parcel: 126061570

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1023-09100
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2024 Residential Building APPROVED
01/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/03/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Paul Camaren

PROJECT: TC-RES-1023-09100
Address: 4034 E Roberts Place. Tucson, AZ. 85711
Parcel: 126-06-1570
Zoning: R-1
Existing Use: Single Family Residence
Project Description: Accessory Dwelling Unit Addition

TRANSMITTAL DATE: 1/3/2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence with an Accessory Dwelling Unit is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9, and 6.6.3.

1. COMMENT: This comment is still applicable please provide a dimension from design grade to midpoint of the roof. Per UDC Article 6.6.3.D, “Accessory structures shall not exceed 12 feet in height.”
Per UDC Article 6.4.4.A, “Building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge ) of the highest gable of a pitched or hipped roof.”

1. COMMENT: label elevation drawing with cardinal directions, The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a calculated wall height of 10’-2” the required perimeter yard setback from the proposed accessory structure to is 8’-2”, if you are unable to meet the required setback at a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the east:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf . The completed application shall be submitted as a PDF under assigned permit number . If you have questions about the DDO application or process please contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
01/02/2024 PDSD Application Completeness Express REVIEW COMPLETED