Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.5
Permit Number - TC-RES-1023-08886
Review Name: RESIDENTIAL SIMPLE REVIEW v.5
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/08/2023 | Site Engineering | NOT REQUIRED | |||
11/09/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/08/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Since this structure was previously constructed without a permit as allowed under a Building Code exception, significant changes will likely be necessary to add electrical service to this structure. When electrical service is added to the shed, is now is required to be permitted and comply with Building code requirements. 2. Submit a complete set of construction drawings to indicate compliance with the 2018 International Residential Code including but not limited to the following R106.1. A. Site plan with setback distances from structures and property lines as structures less than 3 feet from the property line must have fire resistive rated exterior walls of 1 hour—tested in accordance with ASTM E119,UL 263 or Section 703.3 of the International Building Code with exposure from both sides. IRC TABLE R302.1(1) B. The foundation is required to be 12” wide by 6” thick with the bottom of the footing 12” below natural undisturbed soil and be 6” above finish grade if supporting wood framing above. IRC Chapter 4. With ½" anchor bolts embed a minimum of 7” and spaced a maximum of 6 feet apart per R403.1.6 C. Concrete slab on grade is required to be a minimum of 3- ½" thick. IRC R506. D. Please provide drawings to graphically portray the construction of the shed to include the above code requirements and show the framing to follow the requirements of IRC Chapter 6 (Walls) and Chapter 8(Roof). Include all connections and provide an attachment schedule per TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS. F. Provide a complete code compliant drawing with next submittal. R106.1 |
||
11/09/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-1023-08886 555 N PANTANO RD Unit:UNIT 551 Zoning MH-1 TRANSMITTAL DATE:November 9, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. As mention in the comment response letter, building plan are not required when a detached accessory structures 200 sf or less in area and don't have electrical, but a site plan is needed to verify setbacks, height, and other zoning standards. Building plans are not required. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf This shall in include but not limited to: a. Zoning of adjacent parcels b. All Utility lines c. owner information d. setback information 2.COMMENT: Provide the height of the structure. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
11/02/2023 | PDSD Application Completeness | REVIEW COMPLETED |