| 10/18/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/18/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1023-08882 (325 E ROGER RD TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Note and specify all piping materials and sizes, P2609. 2. The 5-foot segment to the furnace requires a minimum size of ¾” pipe per Table G2413.4(1). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||