Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.3
Permit Number - TC-RES-1023-08828
Review Name: RESIDENTIAL SIMPLE REVIEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/25/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/25/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). The segment of pipe between the meter and the gas pack branch should be 1-1/4" . Provide an updated plan. Also, install a carbon monoxide detector near the bedroom area, R315. | ||
| 10/24/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |