Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1023-08806
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/27/2023 | Site Engineering | NOT REQUIRED | |||
| 10/20/2023 | Site Zoning | NOT REQUIRED | |||
| 10/31/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/31/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-1023-08806 (138 W DRACHMAN ST TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Electrical Review: 1. Show locations of each smoke alarm, R314. The North bedroom is missing a smoke/CO alarm. When ceiling finish materials are removed in existing construction, existing bedrooms must be brought into compliance. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke alarms, R314.2. 2. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity. The North bedroom is missing a smoke/CO alarm outside the doorway. 3. OCPD for copper conductor may not exceed 15A for #14, 20A for #12 or 30A for #10 rating required by E3705.5.3(small conductors). Circuits 5/7 for the oven shows a #10 wire, this is undersized for the given OCPD of 50A. 4. Provide the manufacturer’s specification sheet for the new tankless water heater, and indicate if it is gas fired or all electric. 5. Show Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. 6. Show all receptacle outlets serving kitchen countertops and dishwasher with GFCI, E3902.6. 7. Show all laundry area 120-volt receptacle outlets 15 & 20 AMP with GFCI protection, E3902.9. Plumbing Review: 8. If the new tankless water heater is gas fired, Provide a gas pipe plan. 9. Note and specify all piping materials and sizes, P2609. 10. Show connection lengths from gas meter to all gas appliances. G2401.1, , G2413.1, R301.1: See https://www.tucsonaz.gov/files/pdsd/permits/GAS_HANDOUT_2018_IRC_2019.2.4.pdf https://www.tucsonaz.gov/files/pdsd/permits/Gas_Piping_Template.pdf https://www.tucsonaz.gov/files/pdsd/permits/Sample_Gas_Template_0.pdf 11. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. 12. Provide protection of (indoor rated, new tankless waterheater) equipment located outdoors with an exterior rated enclosure, G2406.3. 13. A minimum 3/4” pipe is required for supplying water to the bathroom group fixtures. ½” pipe can be used for each individual fixture. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 10/16/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |