Permit Number: TC-RES-1023-08790
Parcel: 12407022C

Address:
234 N EUCLID AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1023-08790
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/27/2023 Site Engineering NOT REQUIRED
10/31/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
10/31/2023 Residential Building REQUIRES RESUBMIT TC-RES-1023-08790
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

SITE PLAN:

Remove outdated note #11 as this is covered with note #1, R106.1.1.

SECTIONS - DETAILS:

1. Attic space requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2. Provide appropriate upper and lower space vents when applying the reduced area calculation. Account for the existing attic space if removing or blocking existing vents.

MECHANICAL PLANS:

1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. Systems shall be sized in accordance with building loads calculated in accordance with Manual J.

ELECTRICAL PLANS:

1. Provide a Riser Diagram showing a sub panel and feeder size, NEC 225.30, E3403, Table E3704.2(1).

OUTDOOR LIGHTING CODE

1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
10/18/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-1023-08790
234 North Euclid Avenue – R-2
Addition (1st Review)

TRANSMITTAL DATE: October 18, 2023

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

1. Provide a lot coverage calculation on the site plan. Lot coverage includes the area of the lot covered by buildings, outdoor storage, and vehicular use areas, whether paved or unpaved. Lot coverage shall not exceed 70% of the total lot area (UDC 6.3-2.A).

2. A detached accessory structure appears in the front yard beginning in 2002. The Zoning Review Section was unable to determine whether a compliance review was obtained for this structure.

Per UDC 6.6.3.C, detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. A Board of Adjustment variance is required to be granted to allow the structure to remain detached in the front yard. If the structure is to be removed, indicate its new location, or notate that it will be removed from the site.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
10/16/2023 PDSD Application Completeness REVIEW COMPLETED