Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-1023-08761
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/02/2024 | Residential Building | REQUIRES RESUBMIT | 1. Show rafter to beam connection using (H2.5) ties having a resistance to uplift of not less than 365 pounds, R802.11.1. (City of Tucson Amended). 2. Show ledger to wall connections consistent with Figure R606.11 (1) or an engineer's performance compliance. |
||
| 05/02/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-1023-08761 622 North 10th Avenue – R-3 Detached carport – CE-VIO0423-02819 (2nd Review) TRANSMITTAL DATE: May 2, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 3. This comment has not yet been addressed. Site Zoning acknowledges a Design Development Option (DDO) application has been submitted to allow the front wall to exceed the maximum height of a perimeter wall as prescribed within UDC 6.6.2.I.2. Zoning cannot approve TC-RES-1023-08761 until the submitted DDO is approved. 4. This comment has not yet been addressed. Perimeter yard setbacks are based on a measurement from the design grade elevation to the highest point of an exterior building wall (see UDC 6.4.5.B and Figure 6.4.5-A). A vertical structural member such as a post supporting a roof extension is considered a wall for applying perimeter yard requirements (UDC 6.4.5.B.2). Based on a wall height less than 9’-0”, the required perimeter yard is 6’-0” measured from the posts of the carport to the south lot line. Provide a dimension from the posts of the carport to the south lot line. As a neighbor’s setback waiver cannot be obtained, and as it appears the posts of the carport are one foot or more from the south lot line, a DDO may be utilized to reduce the side perimeter yard. Contact Mark.Castro@tucsonaz.gov if you have questions about the DDO process. If you have any questions about this review, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 04/03/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 05/13/2024 | Zoning Modifications - DDO | REVIEW COMPLETED | FROM: Georgia Pennington, PLANNER DATE: 5/13/24 COMMENTS: 1. As the comment response states a Board of Adjustment variance will be applied for, please include your wall height increase in your Board of Adjustment application. If you have any questions, please contact me at georgia.pennington@tucsonaz.gov |