Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1023-08649
Parcel: 137031380

Address:
5221 S 6TH AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1023-08649
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/11/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
10/11/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1023-08649 (5221 S 6TH AV TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

Plumbing Plan:
1. Notate and specify all piping materials, P2608.
2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Tucson Water Department limits 5/8" water meters to a maximum of 11 IRC fixture units or 15 gallons per minute.
3. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.6. & P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
10/10/2023 PDSD Application Completeness REVIEW COMPLETED