Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-1023-08572
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/11/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/11/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1023-08572 (331 N OLSEN AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. The main segment into the Main House requires a 1 ¼” poly pipe per Table G2413.4(7). Branch length ~85’ per G2413.4.2. (current size shows 1" poly). 2. The segment to the main house furnace and water heater requires a 1” BIP per Table G2413.4(1). Branch length ~85’ per G2413.4.2. (current size shows 3/4" BIP). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 10/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |