Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/08/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/08/2023 | Historic | REQUIRES RESUBMIT | The Special District minor review application submittal is complete. Please submit all the same materials under the Historic sub-record. Review fee pending payment. Once paid a minor review will be scheduled. See link below for steps on resubmitting. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions, contact Michael Taku at Michael.Taku@tucsonaz.gov or 520 837 4963. |
||
10/16/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1023-08543 (821 S 2ND AV TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Structural Plans: 1. For wind uplift use 115 mph in 3sec gust, Table R301.2(1). https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf >> Provide the following structural calculations. 2. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems 3. When applying for a permit to place new equipment on existing code-compliant roofs constructed in the past fifty years, an allowance shall be provided for equipment weighing a maximum of 4 psf and load per attachment point of 40lbs or less, R324.4. Provide plans showing compliance with these prescriptive design requirements, or provide an engineer’s calculation, and sealed design. https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Development%20Services/Building/Equipment%20on%20roofs%20.pdf Electrical Plans: 4. Show the supplemental grounding rod in compliance with E3608.4. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
10/24/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: TC-RES-1023-08543 Plot Plan Review (1st Review) 821 S 2nd Av / HO-3 TRANSMITTAL DATE: 10/24/2023 1. The property is located in a historic zone (HO-3). Historic approval is required prior to zoning approval. For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov |
||
10/04/2023 | PDSD Application Completeness | REVIEW COMPLETED | |||
10/12/2023 | Site Engineering | REVIEW COMPLETED |