Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1023-08485
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2023 | Site Engineering | NOT REQUIRED | |||
| 10/24/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/24/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1023-08485 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Wooden structures may not be supported by a mobile home. A special inspection request is required with the permit application for field welding, R109.2. Show manufactured assemblies without field welding or submit a privately acquired certified inspector request form for approval. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location and size of buildings, utility meters and lines supporting the alterations, R106.1.1. Show the utility lines requiring upgrade or replacement. 2. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2) or provide a Pima County processed utility easement preventing construction within 3 feet of the structure on the neighboring property. STRUCTURAL PLANS: 1. Show the location of each support footing, R106.1.1. 2. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. SECTIONS - DETAILS: 1 Show reinforced footing dimensions required for post/beam construction, R403.1.1. 2 Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1. 3 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. ELECTRICAL PLANS: 1. Show any electrical alterations. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |
||
| 10/20/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-1023-08485 8021 S Farmbelt Dr– SH Additions (1st Review) TRANSMITTAL DATE: 10/20/2023 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This plan at a minimum shall: - Show all structures and indicate all property boundaries - Provide the height for all structures. - Show the entire parcel - Provide the proposed setback for the structure. At the bottom of this link you can find an existing site plan documents for this property that can be updated and used to show the area of the patio addition. The document type will be labeled “CONSTRPLANS”: https://pro.tucsonaz.gov/permitdetails/T00CM03447/ Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov |
||
| 10/09/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |