Permit Review Detail
Review Status: Approved
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1022-00213
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/06/2022 | Light Residential Building Review (OIP) | APPROVED | |||
| 12/06/2022 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 11/30/2022 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Existing structure has not been verified by the installer. “2x4 truss” construction is indicated as presumed. Engineer’s assessment of the structural capacity of the existing construction has not been provided by the applicant. Conformance to structural requirements of IRC R324.4.1 cannot be verified by the reviewer. Required 18 inch panel setback from the roof ridge (at panel side) shall be provided at panel segment #2 and panel segment #3. (IRC R324.6.) Roof penetrations shall be flashed in accordance with IRC R324.4.3 |
||
| 11/02/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |