Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1022-00213
Parcel: 136212780

Address:
2931 S MARVIN AV

Review Status: Approved

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-1022-00213
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
12/06/2022 Light Residential Building Review (OIP) APPROVED
12/06/2022 Bldg Permits - Post Review Express REVIEW COMPLETED
11/30/2022 External Reviewers - SAFEBuilt REVIEW COMPLETED Existing structure has not been verified by the installer. “2x4 truss” construction is indicated as presumed.
Engineer’s assessment of the structural capacity of the existing construction has not been provided by the applicant.
Conformance to structural requirements of IRC R324.4.1 cannot be verified by the reviewer.
Required 18 inch panel setback from the roof ridge (at panel side) shall be provided at panel segment #2 and panel segment
#3. (IRC R324.6.)
Roof penetrations shall be flashed in accordance with IRC R324.4.3
11/02/2022 PDSD Application Completeness Express REVIEW COMPLETED