Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1022-00199
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/12/2023 | Site Zoning | APPROVED | |||
| 12/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/11/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1022-00199 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide the permit number for the existing Carport and walls shown as existing or clarify the plans with notation of “built without permit”. SITE PLAN: 1. Show the attached 102 SF Storage with one-hour fire-resistive construction in compliance with IBC Table 721.1(2) or remove the non-compliant structure. 2. Show the location and size of the water and sewer lines from the point of connection to the proposed sleeping quarters, R106.1.1. STRUCTURAL PLANS: 1. Clarify the roof framing plan showing the portion existing as part of the existing carport, R301.1. PLUMBING PLANS: 1. Show an individual accessible water supply shut off for the proposed sleeping quarters, P2903.9.1. MECHANICAL PLANS: 1. Show dryer vent size and location for venting to exterior, M1501. ELECTRICAL PLANS: 1. Provide a feeder load calculation for the new sub-panel as shown at Table E3704.2(1). The 40% reduction does not apply for a sub panel as with the primary service calculation. Include the water heater and second mini-split unit. 2. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description showing a separate bathroom circuit, water heater and second mini-split unit, E3404.13 & E3706. 3. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. OUTDOOR LIGHTING CODE Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 11/28/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |