Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1022-00199
Parcel: 126162200

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1022-00199
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2022 NPPO APPROVED
11/15/2022 Site Engineering NOT REQUIRED
11/21/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/15/2022 Residential Building REQUIRES RESUBMIT TC-RES-1022-00199
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions and concerns before permit approval.

GENERAL COMMENTS:

1. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the as-built Storage addition details with necessary alterations for achieving code compliance or provide the permit number with a completed final inspection for this structure requiring fire rating compliance.

SITE PLAN:

1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify a feeder line and sub panel location. Multiple branch circuits between buildings is not compliant.

FLOOR PLANS:

1. Show a north arrow on the floor plan, R106.1.1.
2. Provide a landing with minimum 36” depth at the door, R311.7.6.

STRUCTURAL PLANS:

1. Provide a roof framing detail with the ledger fasteners showing appropriate load carrying capacity, R106.1.1. Or show a permit number of the extended block wall with ledger inspection.

ELECTRICAL PLANS:

1. Show a single feeder or branch circuit to the accessory (detached) building, NEC 225.30.
2. Provide an electrical riser diagram showing the sub panel, feeder size and protection, E3403. .
3. Provide a sub-panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
11/03/2022 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-1022-00199
Carport to Office
3935 E CALLE DE JARDIN Zoning R-1

TRANSMITTAL DATE:‎November 3, 2022


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

After looking at the subdivision map, there is a 10ft utility easement located on the north end of the property. It appears that the existing storage might be in this easement please clarify.

1.COMMENT: When converting a detached non-habitable space to habitable a DDO or Neighbor sign off is required.

Zoning is unable to write DDO comment please provide the setback from the structure to the property line,
2.COMMENT: The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). At a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the south and to the west:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://tdc-online.tucsonaz.gov”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.




If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
11/03/2022 PDSD Application Completeness Express REVIEW COMPLETED