Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0926-05451
Parcel: 137336490

Address:
6235 S LOGGER DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0926-05451
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/02/2026 Residential Engineering NOT REQUIRED
10/09/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/06/2026 Residential Building - Standard REQUIRES RESUBMIT Please provide a framing and roof plan along with an electrical plan if any outlet or lights are being installed. See the link below for examples.

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits
10/09/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Drew Szentesy
Planner
PROJECT: TC-RES-0926-05451
6235 S LOGGER DR TUCSON, AZ 85746
Patio

TRANSMITTAL DATE: 10/09/2026

This site is located within the R-1 zone (UDC 4.7.8). An single family dwelling is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9, & .12.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Please include all details found in our basic site plan requirements. Our basic site plan can be found here for reference: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf
2. Please include the name of the property owner on the site plan.
3. Please include the zoning classification on the site plan which is R-2.
4. Please include a scale bar and north arrow.
5. Please include property line dimensions. This can be found here as lot 393: https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=52058
They appear to be 124.49’ to the north, 45.01’ to the east, 118.4’ to the south and 45’ to the west.
6. Please include setbacks between all structures and adjacent property lines. This includes the primary dwelling and porch
7. Please include the dimensions, heights and materials of all existing structures including the rear-patio structures.
8. Please include lot coverage calculations by showing the following:
a. Show square footage of the parcel
b. Total square footage of all enclosed structures
c. Total square footage of all vehicular use areas
d. Add a lot coverage calculation, which is the percentage of the site occupied by enclosed buildings and vehicular-use areas

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
For questions regarding Zoning comments, please contact me at: Drew.Szentesy@tucsonaz.gov
10/01/2026 PDSD Application Completeness Express REVIEW COMPLETED