Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0926-05254
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/21/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Provide a comment response letter and address the following comments: 1) Provide load calculations including the EV charger (Standard or Optional are accepted). As of Jan. 1, the City of Tucson has adopted the 2024 I-codes and 2023 NEC. Verify that all calculations adhere to the variables present in the new code. EVSE to be calculated at a minimum of 7.2 kW or nameplate rating, whichever is greater. Conductors and OCPDs are to be sized as continuous loads (80% rule) 220.57 2) Provide Manufacturer Specifications of the EV charger to be used. Include any certifications to ensure that the EVSE is UL listed E3403.3 3) Show the location of the EV charger is protected from vehicular impact, indicate return wall depth or show method that will protect the charger and associated electrical equipment E3404.10, 110.27(B) 4) EV charger must be GFCI-capable, alternatively provide a means of GFCI protection (including GFCI Overcurrent Protection Devices (OCPD)) 625.54 5) Provide manufacturer specifications and wiring diagram for the proposed EVSE to verify whether a grounded conductor (neutral) is required for the installation. Installation shall comply with NEC 110.3(B), 220.61, and 625.42. 6) Include the equipment grounding conductor (EGC) size on the plans. Provide total conductor quantity and overcurrent protection details sufficient to verify compliance with NEC 210.19, 240.4, and 250.122. 7) Show the location of the electrical equipment with clear working space compliance, working space must be WITHIN the property line 110.26(A) 8) Please provide a site plan showing the proposed location of work (address) under this permit, including the applicable trade work and any associated equipment, alterations, additions, or replacements. Provide sufficient information to demonstrate compliance with the applicable general requirements for simple trade work and to establish the extent of work being performed. IBC 105.3 |
||
| 09/21/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |