Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0926-05229
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/23/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have questions regarding this review, please contact PDSD-Permits@tucsonaz.gov Parcel/addressing issue. The site plan shows to be for an ADU (Accessory Dwelling Unit). The location does not have units attached to the address. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. After address/units have been added or verified you'll need to submit an address change request to update this record along with a new aerial/site plan that shows the corrected addressing. |
||
| 09/24/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0926-05229 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Show the utility meters and lines from the utility source to the ADU, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Clarify the location of keynote #11 & 12. SECTIONS - DETAILS: 1. A vented attic does not require the R-5 rigid insulation at the roof sheathing, R806.5. ELECTRICAL PLANS: 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 2. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 3. Provide GFCI protection for appliance receptacle outlets, E3902.12 & 14. Include the Clothes dryer and HVAC equipment. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Specify high-efficacy luminaires with an efficacy not less than 45 lumens per watt or lamps with efficacy not less than 65 lumens per watt (LED devices), IECC R404.1. Remove or update note #26 & 32. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 09/25/2026 | Residential Engineering | REQUIRES RESUBMIT | Site Engineering Review TC-RES-0926-05229 4455 E WHITMAN ST Description: Convert Garage into ADU Date of Review Transmittal: 9/25/2026 City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf Site Engineering comments are as follows: 1. Dimension and describe the composition of the Accessible Route to the ADU’s main entryway. 2. Site plan keynotes 11 and 12 on sheet A1 appear to be swapped. Please review and confirm utility locations. 3. Ensure the electric sub-panel does not reduce the width of the accessible route to less than the minimum width of 4-ft. 4. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles. *Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed* To re-submit, visit the Tucson Development Center Online at: https://tdc-online.tucsonaz.gov/#/home Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
||
| 09/25/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0926-05229 – Residential Building 4455 E Whitman St, Tucson, AZ 85711 Residential ADU – Casitas (1st Review) TRANSMITTAL DATE: September 25th, 2026 This site is located in the R-1 zone (UDC 4.7.9). An accessory dwelling unit is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8, & 12, and 6.6.3. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) Per UDC 7.6.8, all new residential developments consisting of 1-4 units require basic native, drought resistant landscaping to be added to the site plan. a. Per UDC 7.6.8.A.1, one canopy tree is required for every 1,000sqft of GFA of the development project. This project will require 1 canopy tree. b. Per UDC 7.6.8.A.2, 5 square feet of vegetative groundcover is required for every foot of front street frontage, minus the width of the curb cuts. Please show and dimension this area on the site plan. c. Provide plant species for both the vegetative groundcover and canopy trees to ensure that they are ADWR Low Water Use approved plant species. See the link below to learn more about approved plant species. d. Existing landscaping may be used to meet landscaping standards but must be indicated and labeled on the site plan. To learn more about the new residential landscaping code, please visit the following link: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 09/23/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |