Permit Number: TC-RES-0926-05201
Parcel: 137314230

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0926-05201
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/18/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this request, please email PDSD-Permits@tucsonaz.gov

1) The water heater make/model supplied does not adhere to the minimum Uniform Energy Factor requirements based on the 2024 IECC R403.5, Table R408.2.3 (UEF on the model provided is .66 maximum; required minimum is .81 UEF for gas-fired water heaters). Please provide documentation that the new water heater being installed meets the minimum .81 UEF per the 2024 IECC.

Step-by-Step instructions on how to resubmit:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
09/18/2026 PDSD Application Completeness Express REVIEW COMPLETED