Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0926-05112
Parcel: 134242720

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.1

Permit Number - TC-RES-0926-05112
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2026 Residential Building APPROVED
09/21/2026 Residential Zoning APPROVED
09/29/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/29/2026 Residential Engineering REQUIRES RESUBMIT Reviewer: John Mounsey – Engineering Associate
Reviewer Contact Information: john.mounsey@tucsonaz.gov

BUILDING PERMIT (TC-RES-0926-05112)
The Construction Plans must be updated to include the following:
1. The calculated base flood elevation (BFE) of 2617.0-FT NAVD88 and the required regulatory finished floor elevation (FFE) of 2618.0-FT NAVD88 on the site plan. Show with a general note that the entire parcel is located in FEMA XS100 floodplain. Show FFE on the proposed structure footprint.
2. Due to the property location in the floodplain, the new detached ADU must be built to floodplain standards. Use the FFE of 2618.0-FT NAVD88 (or higher if the grading plan shows a more conservative elevation). Provide a stamped grading sheet prepared by a licensed Arizona Civil Engineer with this submission. See the FPU permit comments (TE-FPU-0926-00381) on TDC-Online for all required grading plan items.
3. Accessible Route (acknowledged): The Inclusive Home Design Ordinance requires a clearly defined, accessible walkway from the street, sidewalk, or driveway to an entrance of the ADU. This pathway must be shown, dimensioned, and labeled on your plans and must meet 2017 ICC A117.1 Sections 402 and 403 standards. [Link to Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf] NOTE: Due to the elevation requirement for the structure in a floodplain, a waiver of provisions of this standard maybe waived by requesting a Building Official Appeal in the sub-records of this permit. The appeal must state why the exterior route shows practical difficulties with the standards.
If you have further questions about these permits or development within floodplain, please contact John Mounsey.
John.Mounsey@tucsonaz.gov.
09/15/2026 PDSD Application Completeness Express REVIEW COMPLETED