Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0926-05012
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2026 | Residential Zoning | APPROVED | |||
| 09/16/2026 | Residential Engineering | NOT REQUIRED | |||
| 09/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/17/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0926-05012 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Provide a separate response letter addressing each comment with location of change on the plans. PLANS: 1. Show the functional name of each existing adjacent room, R106.1.1. Existing bedrooms with removed windows or exit doors require code compliance for emergency egress, R319. Include any alteration of existing bedroom openings between existing and proposed rooms. 2. Show compliance with R325.1 providing (4%) natural ventilation into the proposed room or identify a mechanical ventilation appliance/device. 3. Provide a landing at all exterior doors. A landing must be at least as wide as the door it serves and 36” in the direction of travel, R318.3. SECTIONS - DETAILS: 1. Provide a wall section detail with 12” x 12” reinforced foundations for anchoring exterior framed walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 09/11/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |