Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0926-04992
Parcel: 140191610

Address:
700 E BANTAM RD

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0926-04992
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/17/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/17/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0926-04992
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance.

Place the current reference code on the 1st sheet of a page numbered construction plan set.

The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Provide an Arizona engineer’s calculation, design, and seal for a performance design when minimum sizes are not prescriptive code compliant with the IRC, R301.1.

Provide a separate response letter addressing each comment with location of change on the plans.

SITE PLAN:

1. Show the utility meters and lines from the utility source to the building, R106.1.1. Identify the location of electrical lines running to the service panel and to the proposed structure.

PLANS:

1. Provide a detailed construction plan set with engineering seal by a registered Arizona engineer showing wind loading compliance, R301.1.

SECTIONS - DETAILS:

1. The roof projection (overhang beyond beam) may not extend closer than 24” to the adjoining (neighboring) property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended).

ELECTRICAL PLANS:

1. Provide a Riser Diagram showing the feeder size to the detached structure panel, E3406 and E3801.
2. Show GFCI protection for receptacle outlets, E3902.3.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
09/16/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner
PROJECT: TC-RES-0926-04992
700 E. Bantam Rd., Tucson AZ 85706
Shed (1st Review)

TRANSMITTAL DATE: 09/16/2026

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6., 8., & 9. for 2 units.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Provide a site plan. Site plan requirements are located at the following link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples. We will need the Full site plan if the project has utilities and if it is over 200 sf.

Part of the site plan requirements is to provide the lot’s dimensions. The dimension of Lot 55, as shown on the Pima County Assessor’s Office map of the Los Olivos Estates subdivision found at https://www.asr.pima.gov/ParcelData/Map/Arm/MP33/33046.PDF is 53’ wide at the rear (south end); 29.11’ at the front (north end) with a 36.19’curve at the NW corner; 116.83’ along the east side of the lot; and 92.27 along the west side of the lot.

The rear and east building setbacks are 5’. The side setback along S. 1st Ave is 10’, and the front building setback is 20’. These setbacks are found in the Unified Development Code (UDC) Table 6.3-2.A https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-4860

2. With the next submittal cycle, please provide the following:
a. The completed site plan
b. Construction plans
c. Response letter explaining how all staff comments have been addressed.

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov
09/11/2026 PDSD Application Completeness Express REVIEW COMPLETED