Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0926-04956
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/04/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/04/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact PDSD-Permits@tucsonaz.gov Please resubmit addressing the following comments: 1) The 1” main line pipe is undersized for the given length and total appliance demand (235,000BTU). And the 1/2” pipe to the 100,000 Furnace is undersized. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe) Note: Indicate any transitions in material from one section to another (e.g. underground poly to above-ground black iron). |
||
| 09/04/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |