Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0926-04956
Parcel: 12911095A

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0926-04956
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/04/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/04/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this Review, please contact PDSD-Permits@tucsonaz.gov

Please resubmit addressing the following comments:
1) The 1” main line pipe is undersized for the given length and total appliance demand (235,000BTU). And the 1/2” pipe to the 100,000 Furnace is undersized. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe) Note: Indicate any transitions in material from one section to another (e.g. underground poly to above-ground black iron).
09/04/2026 PDSD Application Completeness Express REVIEW COMPLETED