Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0925-04788
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/30/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/30/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | PDSD Residential Review Section PROJECT: TC-RES-0925-04788 Main Gas Line Replacement-(1st Review) (5417 E 8TH ST TUCSON) TRANSMITTAL DATE: September 30th, 2025 Comments: 1) The ¾” main line pipe is undersized for the given length (80ft)and total appliance demand (175,000 BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. Please resubmit a revised gas template to include the type of pipe used and adequate pipe size based on the appliance demand. Please email any questions to: PDSD-Residential@tucsonaz.gov |
||
| 09/30/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |