Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0925-04788
Parcel: 127081030

Address:
5417 E 8TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0925-04788
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/30/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/30/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section PROJECT: TC-RES-0925-04788 Main Gas Line Replacement-(1st Review) (5417 E 8TH ST TUCSON)
TRANSMITTAL DATE: September 30th, 2025

Comments: 1) The ¾” main line pipe is undersized for the given length (80ft)and total appliance demand (175,000 BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. Please resubmit a revised gas template to include the type of pipe used and adequate pipe size based on the appliance demand.

Please email any questions to: PDSD-Residential@tucsonaz.gov
09/30/2025 PDSD Application Completeness Express REVIEW COMPLETED