Permit Number: TC-RES-0925-04759
Parcel: 11618254B

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0925-04759
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/20/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/20/2025 Residential Building - Standard REQUIRES RESUBMIT Provide a complete construction plan set showing 2018 IRC and City of Tucson building ordinance compliance after DDO approval.

Clarify the square footage for all the new area labeled on the plan.
10/10/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Ramiro Olivarez
Zoning Review Section

PROJECT: TC-RES-0925-04759
1039 W CONGRESS ST – R-2 Zoning
Remodel of existing single family residence. (1st Review)

TRANSMITTAL DATE: 10/10/2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. Comment: Correct the rear alley width dimension to 15’.

2. Comment: Include the total lot coverage Percentage in the project information.

3. Comment: The area where the proposed new bedroom and office are located was previously permitted as a patio. The attached demolition plan depicts this area as storage rooms; however, no permit history or documentation could be found for the enclosure of these spaces.

Enclosing the existing patio to create livable space constitutes a change of use.

As such, the proposed bedroom and office must comply with the dimensional standards outlined in UDC Table 6.3-2.A.

In an R-2 zone, the minimum setback to an interior property line is 6’ or 2/3 the height of the adjacent wall. The depicted setback is 3’ 4” (as shown on the site plan), the minimum setback to the eastern property line is 6’. Only 3’4” setback to the east property line is depicted on the site plan.

A Design Development Option (DDO) application will be required to be submitted and approved before final Site Zoning approval can be provided for this permit.

For more information about the DDO process, including an application, see https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

If you are interested in moving forward with the DDO to allow the reduced setback, upload the DDO application to the “Zoning Modifications/DDO” subrecord on this permit within TDC Online. For instructions on creating a subrecord, please see https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

Once approval of the DDO is provided in a DDO Decision Letter, upload that letter and resubmit this permit following the two-week post-decision appeal period.

4. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide updated site plan in the next submittal.

If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov
10/02/2025 PDSD Application Completeness Express REVIEW COMPLETED