Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.1
Permit Number - TC-RES-0925-04748
Review Name: RESIDENTIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/17/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/14/2025 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | 1. Please state the height and total length of the fence on your plans. Just so you are aware, any wall or fence over 7ft will require a engineer's review if you go that route. | ||
| 10/17/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0925-04748 4044 E North St., Tucson, AZ 85712 Fence Repair and Expansion (1st Review) TRANSMITTAL DATE: 10/17/2025 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. The submitted plan does not include enough information for zoning review. Please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example . Please revise the plot/site plan to include the information provided in the link, including the elevation of the fencing as indicated in a Site Engineering comment. 2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. For questions regarding Zoning comments, please contact me at: Roxanne.Johnston@tucsonaz.gov. |
||
| 10/03/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TC-RES-0925-04748 Location: 4044 E NORTH ST Review Date: 10/3/2025 Site Engineering Comments: 1. A better site plan will be required to show more of what exactly is being done. 2. This property resides within the COT Alvernon Wash floodplain and will require a floodplain use permit. This is a separate permit that can be applied for within the sub-records of this residential permit. 3. Due to the floodplain, flood venting for the fence will be required. Since it appears to be a wooden fence, this would require that 6-inches from natural grade and up be clear to allow for proper flow for the entirety of the fence line. 4. For resubmission of this residential permit, and submission of the FPU permit, provide a fence detail to show this 6-inch clearance requirement If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/01/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |