Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0925-04668
Parcel: 11106135A

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0925-04668
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/23/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/23/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section
PROJECT: TC-RES-0925-04668 Gas Line from meter to furnace, Range, Water Heater and Dryer-(1st Review) (3608 E MONTE VISTA DR)
TRANSMITTAL DATE: September 23rd, 2025

Comments: 1) The 1” main line pipe is undersized for the given length (103') and total appliance demand (235,000 BTU) using Table G2413.4(1) (Metallic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing per G2413.4.1. Please resubmit a revised gas template showing an adequate pipe size from the meter to the farthest appliance.
09/23/2025 PDSD Application Completeness Express REVIEW COMPLETED