Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0925-04639
Parcel: 123052730

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU REVISION v.1

Permit Number - TC-RES-0925-04639
Review Name: RESIDENTIAL ADU REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/24/2026 Residential Building REQUIRES RESUBMIT Per IRC R302.1 a 1 hour fire rated wall must be tested in accordance with ASTM E119 (or UL263) which covers full fire rated assemblies, not ASTM E-84. The proposed product is not UL listed for 263 and does not qualify as a substitute for a 1 hour fire rated wall assembly.
07/22/2026 PDSD Application Completeness Express REVIEW COMPLETED