Permit Number: TC-RES-0925-04631
Parcel: 126120200

Address:
4628 E 5TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0925-04631
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/28/2025 Site Zoning - Standard NOT REQUIRED
10/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/09/2025 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT Please resubmit addressing the following comments:

1) The sum of supply sources exceeds the maximum allowable capacity for this 100A busbar. The main breaker rating plus all backfed breakers must not exceed 120% of the busbar rating per NEC 705.12(D)(2)

For any questions, please contact: PDSD-Residential@tucsonaz.gov
09/19/2025 PDSD Application Completeness Express REVIEW COMPLETED