Permit Number: TC-RES-0925-04575
Parcel: 136341990

Address:
7501 E 45TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0925-04575
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/15/2025 Residential Engineering NOT REQUIRED
10/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/17/2025 Addressing Validation REQUIRES RESUBMIT The address on the permit TC-RES-0925-04575 (7501 E 34TH ST TUCSON, AZ 85710) does not match the address on the site plans (7501 E 45th St). Please submit a change of address request in this permit's sub records to update the permit address. For help navigating sub records: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf
For questions: PDSD-Residential@tucsonaz.gov
10/09/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0925-04575
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SECTIONS - DETAILS:

1. Clarify the placement of ceiling/roof insulation showing a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Update keynote #8 on sheet A3.0 with consistency with detail #10 on sheet A7.0.
2. Clarify the patio cover sections #7 & 8 on sheet A3.0 showing rafters (joist) extending to the load bearing wall. Connections to the roof overhang tails are not prescriptive, therefore requiring fastener connections designated and sealed by a registrant engineer.
3. Clarify the rafter size shown on details #2 on sheet S2.0 with a porch rafter size consistent with the framing plan.

ELECTRICAL PLANS:

1. Smoke alarms are required outside each separate sleeping area, R314.3.2. Add an alarm in the entry area.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
10/17/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-0925-04575
7501 E 45th St. Tucson, AZ 85710
SFR Additions (1st Zoning Review)

TRANSMITTAL DATE: 10/17/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments have been addressed.

1. Sheet A1.0 shows two existing sheds shown near the north lot lines and a gazebo located in the NW corner of the lot. Staff found no records showing that these were permitted. Sheet A1.0 does not show the measurements from these sheds, and the gazebo, to their respective lot lines and they all appear to be located within the 6’ perimeter setbacks required by the R-1 zone. Please provide measurements from these structures to their respective lot lines so staff can evaluate if they require a variance, a Design Development Option, or can be handled through a Neighbor Waiver process.

2. Lot coverage is calculated based on the square footage of enclosed structures and vehicle maneuvering areas, whether improved or not including driveways, carports and garages and areas used for parking or standing. Please recalculate, and if possible, add the site plan to the same sheet as these calculations.

3. The address entered when uploading the files was 7501 E 34th and did not match the project address. When resubmitting, please ensure the correct address is added.

4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
09/17/2025 PDSD Application Completeness Express REVIEW COMPLETED