Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0925-04508
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/03/2025 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | Please resubmit addressing the following comments: 1) AC Overcurrent Protective Device and Conductor Sizing for PV source Circuits and Module Interconnection Conductors (Imax x 1.25) Reference NEC 690.8(A)(3) and (B)(1). Show a complete calculation for determining OCPD and conductor requirements. (See also 706.21 for ESS) 2) Provide Main Service Panel (MSP) taps in compliance with NEC 705.12; 705.12(B)(2)(3) b Busbars.) 120% bus bar rule. 3) Please indicate on the 3-line graph for how the PCS controls the entire PV system's production |
||
| 09/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |