Permit Number: TC-RES-0925-04339
Parcel: 120062730

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0925-04339
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/04/2025 Addressing Validation REQUIRES RESUBMIT Please include the full property address on all pages of the site plan and resubmit after other reviews are complete.
09/29/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0925-04339
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a response letter on separate file when submitting the updated construction plan set.

Provide all construction plans into a single PDF file.

Provide a clear and concise construction plan set. Review the sample drawings for the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. The side patio roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

SECTIONS - DETAILS:

1 Show location and method of flashing all wall and roof intersections, R903.2.1.

ELECTRICAL PLANS:

1. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. Check with TEP customer service for underground service line options. https://www.tep.com/electric-service-requirements

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
10/03/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0925-04339
326 E District St, Tucson, AZ 85714
Residential Addition/Alteration (1st Review)

TRANSMITTAL DATE: October 3rd, 2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .9 and .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Per UDC Section 6.6.3.C, a detached accessory building is not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. The proposed carport is considered a detached accessory building. A Board of Adjustment Variance would be necessary. More information about the B/A can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Public-Meetings-Boards-Committees-Commissions/Board-of-Adjustment.

2. (Comment) Per UDC Table 6.3-2.A, the minimum side and rear yard setbacks are 6’-0” or 2/3 the height of the exterior wall, whichever is greater. Based on the proposed porch with an exterior column height of 7’-9”, the required setback would be 6’-0”. The indicated setback for the proposed porch is 1’-6” from the west property line.

A Design Development Option (DDO) will be required. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf

For additional questions regarding the Board of Adjustment Variance and DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov.

3. (Comment) The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a, roofed areas and porches that are open on at least one side are not included in the calculation. Remove porch square footage from the lot coverage calculation.

4. (Comment) Provide an engineering scale for the site plan. (Example: 1” = 20’)

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code


For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
09/04/2025 PDSD Application Completeness Express REVIEW COMPLETED