Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.7
Permit Number - TC-RES-0925-04330
Review Name: RESIDENTIAL ADD/ALT v.7
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/10/2026 | Residential Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0925-04330 ADDRESS/PARCEL: (10230 E CALLE ESTRELLA POLAR TUCSON, AZ 85747) Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov. COMMENTS: 1. Per the previous comments that still have not been addressed, your submittal documents require more details for approval (R106.1.1). Please include detail regarding the new rafters sizes, beam sizes, and footers and slab, as well as how it will connect to the existing structure. Please see link below for examples. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/porch_sample.pdf 2. Please submit ALL required documents. The site plan, and the drawings detailing the information above. 3. Please correct and resubmit. |
||
| 01/27/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-RES-0925-04330 – Residential Building – Extending existing backyard porch. new build dimensions to be 16'x16' 10230 E CALLE ESTRELLA POLAR TUCSON, AZ 85747 (O-3 Zoning) Site Plan Review – 4th Review TRANSMITTAL DATE: January 27, 2026 This site is in the O-3 Office Zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3). Plan review for the above referenced porch has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. 1. COMMENT: Not site plan was provided to review against the previous zoning reviewers’ comments to determine if those review comments were addressed or not. The following zoning reviewers’ comments (1a thru h) are reposted for your convenience dated 11/26/26. 1. Zoning cannot accept your site plan until all items a through h, below have been added to the site plan and not in an exhibit. This is necessary because this is a permanent record and used when the applicant or future applicants want to change or add something to the property, and functions similarly to a snapshot in time. This also helps future staff not only share the plan with an applicant but also get an accurate idea of what has been permitted. Please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example. Please complete the following: a. Add the scale to the site plan; for example, 1 inch = 10 feet. b. Add the total square footage of lot, 6,841 to the site plan. c. Add the square footage and outer dimensions of the primary residence - excluding porches to the site plan. d. Add the lot zoning and that of properties that touch the lot (as shown in the response letter) to the site plan. e. On the site plan, show the total lot coverage. This is the square footage of the residence (minus the porches), enclosed sheds, if any, plus the vehicular use areas measured from the edge of the driveway, whether improved or not (interior to the lot) including areas used for movement, standing and parking and any garage or carport. Divide this number by the lot square footage to find the total lot coverage percentage. The maximum lot coverage allowed in the R-2 zone is 70%. f. Show the dimension from the back of the house to the proposed porch addition. This means measuring the distance from the rear of the porch to the back property line. g. Provide the elevations for the porch (North, South, East and West) and measure the height from design grade to the top of the wall – The height is now listed on the site plan, but the elevations (north, south and east) need to be shown in the building plans. Show the height measured from design grade to the top of the exterior wall. h. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected building permit 2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments. 3. Resubmit ALL documents associated with this permit To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 01/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |