Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0924-05486
Parcel: 117063090

Address:
115 N 3RD AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0924-05486
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2024 Site Engineering NOT REQUIRED
10/04/2024 Site Landscape NOT REQUIRED
10/30/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
10/03/2024 Residential Building REQUIRES RESUBMIT TC-RES-0924-05486
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with construction details.

Provide a response letter on separate file when submitting the updated construction plan set.

Clarify of the proposed structure is free standing or attached to the dwelling. Provide the manufacturer specification plan set if pre-designed and purchased as an assembly.

Provide a clear and concise construction plan set if attached to the dwelling. Sample drawings for a wooden Carport are similar to the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. The roof structure attached to the dwelling may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
10/30/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0924-05486
115 N 3rd Ave Tucson, AZ 85705
Addition of temporary carport structure (1st Review)

TRANSMITTAL DATE: 10/30/2024

This site is located in the C-3 zone (Unified Development Code (UDC) Article 4.7.22). A single-family residence is a permitted use in this zone (Table 4.8-4).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Section Review comments were addressed.

1. Comment: The property lines are drawn incorrectly on your site plan. Please draw, label, and dimension the correct property lines for 115 N. 3rd Avenue only as you have included the south property as well.
2. Comment: Please update your lot coverage calculations to only include the property where the proposed carport will be installed. The adjacent property has a separate parcel number and should not be included in the lot coverage calculation.
3. Comment: The proposed carport does not meet the required front street perimeter yard setback which is 20’ (UDC 6.4.5.C.1.a. A Design Development Option (DDO) will need to be submitted and approved to reduce the setback. The DDO application and requirements can be found at http://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Wyatt Berger at Wyatt.Berger@tucsonaz.gov.
4. Comment: Per 6.6.2.B, an accessory building (ie: existing storage) shall be built only on a lot occupied by a principal building meaning the south parcel cannot have the storage sheds located on it unless a lot combination is obtained. You can apply for a lot combination from Pima County at https://www.asr.pima.gov/Downloads/Forms/ComboRequest.pdf
5. Comment: Additional comments may be forthcoming based on corrected plans and responses to zoning comments.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
09/23/2024 PDSD Application Completeness REVIEW COMPLETED